You are here: VibroMatrix Vibration Measuring System > Design & Modules > Event Messengers
DeutschEnglish
2/10/2012

Notepad

What would you like to do?
Please offer me  unit(s) of Variant   
I would like to receive a price list (PDF file by email)
Please answer my questions concerning this product
 

Click here to complete your address: My Notepad

 

 

Downloads

 


Event Messengers

When analyzing vibrations with VibroMatrix, the measured data is displayed optically in the instruments first, or data is saved if required. Event messengers extend the instruments' possibilities of transferring data by additional outputs. Momentarily, these are:

  • Transfer by e-mail
  • Signaling in an extra display
  • Using radio switches

  

Transfer by e-mail (MMail)

Long-term measurements with quite few events are often to run unattended. Interesting events are still to reach the measurement staff.
A suitable way of transmitting data in general is by e-mail. Depending on the instrument, the following VibroMatrix data is transmitted:

  • Single values
  • Status messages
  • Measurement graphics
  • Greater amounts of measurement data

Signaling in an extra display

If VibroMatrix is to be applied for monitoring or inspection tasks (for instance in quality control), work is often divided:

  1. Measurement experts define measurement modes as well as limit values and configure the VibroMatrix instruments acc. to these specifications.
  2. Measurement staff carries out the measurements afterwards. A clear but also simplified view on the measurement result is required.

This simplified view is fulfilled by the messenger extra display. The extra display is a window adjustable in size, which fills out the complete screen if required. It indicates a measured value or status and colors the text color and the background acc. to the configured specifications.

This messenger is included in delivery of VibroMatrix instruments.

 

 

Controlling digital outputs (MDO)

A single VibroMatrix system is able to control hundreds of switching outputs. Therefore, VibroMatrix is combined with the industrial ADAM bus system, which can be equipped with as many switching modules as required. The switching modules are available in different variants and offer:

  • Relay outputs
  • TTL digital outputs
  • Electrically insulated digital outputs

Thus, VibroMatrix - installed stationarily - becomes a powerful alarm system for limit exceedings of vibrations and shocks.

Using radio switches (MRSw)

By means of this messenger, alarm states can be signaled by electric devices. Therefore, the messenger controls a 230V radio switch which switches the power supply of connected loads. These loads can be alarm lamps, horns, flashing lights or other devices as well.

 

The measurement PC (1) is equipped with a single USB radio control center type FHZ 1000 PC (2). It transfers the switching commands to all associated radio switches (3) by radio communication.