Vibration Sensors & Vibration Measurement Equipment
Additional information
Recommended vibration measurement equipment
Measurement, analysis and logging |
|
Signal conditioning |
Vibration monitoring |
|
KS943B.10 - Piezoelectric Accelerometer |
|
| My favorite Units: | |
Overview |
|
|
|
|
|
Transmission | |
| Measurand | vibration acceleration |
| Output | voltage (IEPE) |
| Piezo System | shear design |
Parameter Overview |
|
| Sensitivity | 10 mV/g ± 5 % |
| Measurement Range | -600 .. 600 g |
| Linear Frequency Range | 0.2 .. 22000 Hz |
Measurement Accuracy Sensor |
|
| Transverse Sensitivity | 5 % |
| Temperature Coefficient Total | -0.06 %/K @ -20 .. 120 °C |
| Temperature Coefficient 1 | 0.05 %/K @ -20 .. 20 °C |
| Temperature Coefficient 2 | 0.02 %/K @ 20 .. 80 °C |
| Temperature Coefficient 3 | -0.06 %/K @ 80 .. 120 °C |
| Residual Noise Wideband | 3000 µg @ 0.5 .. 20000 Hz |
| Noise Densities | 300 µg/√Hz @ 0.1 Hz |
| 100 µg/√Hz @ 1 Hz | |
| 30 µg/√Hz @ 10 Hz | |
| 10 µg/√Hz @ 100 Hz | |
| Linear Frequency Range | 0.2 .. 22000 Hz (3 dB) |
| 0.4 .. 17000 Hz (10 %) | |
| 0.6 .. 15000 Hz (5 %) | |
Environmental Characteristics |
|
| Temperature Transients | 0.00300 g/K |
Operating Data |
|
| Operating Temperature | -20 .. 120 °C |
Measurement Limits |
|
| Destruction Limit | 8000 g |
| Resonant Frequency | 42000 Hz |
Mechanical Data |
|
| Weight without Cable | 14 gr. |
| Case Material | aluminium |
| Cabel Connection | Binder 707, radial |
| Mounting | M3 (Y), M3 (Z) |
|
|
|